Bleeding a Boiler

How to Release Trapped Air From a Boiler

Air leaves a boiler system through radiator bleed valves and air vents. Learn where air collects, how each release point works, and which one to use.

On this page
  1. Where air collects
  2. Radiator bleed valves
  3. Automatic air vents
  4. Manual air vents
  5. Purging and topping up
  6. What not to do
  7. When to call a professional

Trapped air leaves a boiler heating system at the points where it collects. In most homes, that means a radiator bleed valve, an automatic or manual air vent, or a high point in the pipework that has a vent fitted. The right release point depends on where the air is and what your system has installed. Switch the system off and let it cool first.

Where air collects

Air is lighter than water, so it rises and settles at high points. The usual places are the top of a radiator, the highest section of a pipe run, the top of an underfloor manifold, and any air separator fitted on the pipework.

If you’re not sure where the air is, start with the radiators. They’re the easiest to reach, and a cold top is the most common sign.

Asking what is used to relieve trapped air in a hydronic system usually leads to two answers: bleed valves and air vents. The sections below cover each one.

Radiator bleed valves

Most radiators have a bleed valve, usually at the top corner. Open it with a radiator key until air escapes with a hiss, then close it once water flows steadily. This is the most common release point and the easiest to use.

The step-by-step process for each radiator, including order, tools, and what to do afterward, is covered under “how do I bleed air from my boiler system?”

Automatic air vents

An automatic air vent releases air without any action from you. Most have a float inside: as air builds up, the float drops and opens a small outlet. Automatic vents are often fitted on the boiler or on a high pipe.

Over time they can stick closed, leak, or fail. A stuck vent is usually better replaced than forced, so ask a heating engineer if it doesn’t work.

Manual air vents

Manual air vents are opened by hand, often with a small key, a screwdriver, or a cap that unscrews. They work like a radiator bleed valve: open it slowly, hold a cloth underneath, and close it once the air is out.

Some manual vents are sealed or hard to reach, so check the boiler manual before you start.

Purging and topping up

Air in parts of the system you can’t reach by bleeding may need a heating engineer. Engineers can purge the whole system, which means moving water through the pipework to carry the air to a release point.

Topping up is a separate step. Add water through the fill valve or filling loop until the boiler gauge is back in its range, then close the valve. Adding water doesn’t remove air by itself, and fresh water carries its own dissolved air, so if you’re topping up often, look for the cause.

What not to do

  • Don’t open a valve or vent you don’t recognize, especially on a gas boiler.
  • Don’t bleed radiators while the boiler is running or the water is hot.
  • Don’t force a stuck valve or vent.
  • Don’t keep topping up without finding out why the pressure is falling.

When to call a professional

Call a heating engineer if air remains after bleeding, a vent is stuck or leaking, the pressure keeps falling, or the boiler shows an error. Anything involving gas should be handled by a qualified person.