Bleeding air from a boiler heating system means opening each radiator’s bleed valve with the system off and cool, letting the trapped air escape, closing the valve, and then checking the boiler’s pressure. The job is simple and needs only basic tools, but take your time and check the pressure at the end.
What you’ll need
- A radiator key, or a flat-head screwdriver for valves that take one
- A cloth or old towel
- A small container or bowl to catch drips
- Gloves, if you have them
- Your boiler manual, for the correct pressure range
Before you start
- Turn off the boiler and let it cool completely.
- Check the pressure gauge while the system is cold, and note the reading.
- Find each radiator’s bleed valve before you start, so you don’t miss any.
- Keep clear of the boiler’s casing and any gas parts. Bleeding radiators doesn’t require you to touch them.
Bleed each radiator
- Start at the first radiator in your chosen order.
- Hold the cloth under the bleed valve. Put the container under it if the radiator is near carpet or floorboards.
- Turn the key counterclockwise to open the valve slowly.
- Listen for hissing. Hold the valve open until the hissing stops and a steady stream of water comes out. The water may be warm, so keep your hands and face clear.
- Close the valve by turning the key clockwise. Snug is enough; don’t overtighten it.
- Wipe up any water.
- Move to the next radiator and repeat.
Choosing an order
“Which radiator do you bleed first, upstairs or downstairs?” comes up often. Many people start with the ground-floor radiators and work upward, while others start with the radiator closest to the boiler. Either way, the important part is bleeding every radiator, not following one exact sequence.
Check the pressure afterward
Bleeding releases some water along with the air, so the pressure often drops. Look at the gauge once you’ve finished. If it’s below the range in your manual, top it up through the fill valve or filling loop, following the instructions. Close the valve or disconnect the filling loop when the gauge is back in range.
Then check the radiators after the system has run for a while. If some are still cool at the top, bleed them again, because air can take time to move through the system.
When a radiator stays cold
- Check that the radiator’s valves are open, including any thermostatic valve turned up.
- Bleed it again after the system has run for a while.
- If it is still cold, the cause may be sludge or a blockage. That needs a professional.
If water keeps coming out or the valve sticks
If the valve keeps dripping after you close it, tighten it gently. If it’s stuck, don’t force it. A worn or damaged valve can often be replaced.
Hot water baseboard heaters
If your home has hot water baseboard heaters instead of radiators, the steps are similar, though the bleed points can be in different places. The guide on bleed air from baseboard heating system covers them.
When to call a professional
- The pressure won’t hold after topping up
- A radiator stays cold or uneven after repeated bleeding
- The boiler shows an error code, leaks, or shuts down
- You’re unsure about anything, especially on a gas boiler