Bleeding Baseboards and Radiators

What Relieves Trapped Air in a Hydronic System?

Automatic air vents, air separators, and manual bleed valves relieve trapped air in a hydronic system. Learn where each sits and what does not remove air.

On this page
  1. The short answer
  2. Automatic air vents
  3. Air separators
  4. Manual bleed valves
  5. What does not relieve air
  6. Keeping air relief working

The short answer

Trapped air in a hydronic system is relieved by automatic air vents and air separators, along with manual bleed valves on each unit. An automatic air vent releases air at high points without anyone turning a valve. An air separator catches small bubbles in the piping and sends them to a vent. Manual bleed valves let you remove air from one radiator or baseboard unit at a time.

Automatic air vents

An automatic air vent is a small valve with a float inside. When air collects in the vent, the float drops and opens a path for the air to escape. When water reaches the vent, the float rises and closes it. Vents are usually placed at high points in the piping or on the boiler.

A vent stuck open can drip water, and one stuck closed cannot release air. Either one usually needs cleaning or replacing.

Air separators

An air separator is installed in the piping, often near the boiler or the circulator pump. It slows or swirls the water so that tiny bubbles rise and collect. The collected air is then released through an automatic air vent or a manual valve.

Manual bleed valves

Each radiator or baseboard unit typically has a manual bleed valve. You open it with a key or screwdriver to let air out by hand. Bleed valves work at the unit rather than across the whole system, so they are best for removing air that has reached a specific unit. For the steps, follow a guide on how to bleed air from a heating system.

What does not relieve air

  • An expansion tank handles water expanding as it heats. It does not vent air from the system on its own.
  • A pressure relief valve opens if pressure gets too high. It protects the system from overpressure, not from air.
  • A fill valve adds water to restore pressure. It does not remove air.

Keeping air relief working

  • Check automatic air vents for leaks, sticking, or dripping. Replace any that leak or fail to close.
  • Keep the boiler pressure within the range on its label.
  • If you keep finding air, ask a technician whether an air separator or automatic air vent is missing, in the wrong place, or failing.
  • Installing a new air separator or air vent is usually a job for a qualified heating technician.