Bleeding a Boiler

How to Get Air Out of a Boiler Heating System

Learn how to get air out of a boiler heating system: bleed the radiators, use the air vents, check the pressure, and find out why air keeps coming back.

On this page
  1. Why air gets into a boiler heating system
  2. Signs that air is in the system
  3. Before you start: safety first
  4. Method 1: bleed the radiators
  5. Method 2: use the air vents
  6. Check and top up the pressure
  7. When the air keeps coming back
  8. When to call a professional

Air gets out of a boiler heating system through radiator bleed valves or air vents. Do this with the system switched off and cooled. Once the air is out, check the boiler’s pressure gauge and top it up if the reading has dropped. If air keeps coming back, something is letting it in, and that cause is worth finding rather than bleeding again and again.

Why air gets into a boiler heating system

In a home hot water heating system, the boiler heats water and a pump moves it through the radiators. Water holds some air dissolved in it. When the water is heated, that air comes out of solution and gathers in pockets, usually at the highest points: the top of a radiator, a high section of pipe, or the top of a loop. Air can also get in when a system is drained and refilled, when fresh water is added, or through a leak or a faulty valve.

This guide covers hot water systems. If your home has steam heat, a steam heating system for home works differently, so these steps may not fit.

Signs that air is in the system

The most common sign is a radiator that is hot at the bottom and cool or cold at the top, because the air pocket stops hot water from filling the upper part. You may also hear gurgling or knocking in the pipes, or notice that some rooms heat more slowly than others.

The symptoms of air trapped in a boiler system can look like other faults, so check the pressure gauge and bleed one radiator before looking for other causes. A cold radiator can also come from a closed valve or a build-up of sludge, which is why it helps to test more than one.

Before you start: safety first

  • Turn off the boiler and let the system cool. Radiators and water can be hot enough to scald.
  • Don’t open or adjust gas parts or the boiler’s casing. If you smell gas, leave the building and call your gas company’s emergency line or your local emergency number.
  • Don’t loosen pipe fittings or open the pressure relief valve on a system that is under pressure.
  • Check your boiler’s manual for its pressure range and any model-specific steps.

Method 1: bleed the radiators

Most radiators have a small bleed valve near the top, at one end. You’ll need a radiator key or a flat-head screwdriver, a cloth, and a small container.

  1. With the system off and cool, hold the cloth under the valve.
  2. Open the valve slowly until you hear air hiss out.
  3. When the hissing stops and a steady stream of water comes out, close the valve.
  4. Move to the next radiator and repeat.

Water can be hot and may spray, so keep your face and hands clear as the valve opens.

Many people also ask, “Which radiator do you bleed first, upstairs or downstairs?” The order matters less than bleeding every radiator and then checking the pressure. If you want the radiator-by-radiator detail, including what to do when a radiator stays cold, read the answer to “how do I bleed air from my boiler system?”

Method 2: use the air vents

Some systems have air vents, which may sit on the boiler, on high sections of pipe, or on a separate air separator. Manual vents open much like bleed valves, usually with a small key or screwdriver. Automatic vents release air on their own through a float mechanism, and they can stick or leak as they age.

Asking what is used to relieve trapped air in a hydronic system leads to the same two answers here: bleed valves and air vents. If a vent is stuck or leaking, don’t force it. A heating engineer can usually replace it.

Check and top up the pressure

Bleeding lets out a little water along with the air, so the pressure often drops. Many boilers are set to about 1 to 1.5 bar (roughly 15 to 22 psi) when cold, but the range on your boiler’s gauge or manual is the one to follow.

If the reading is below that range, top it up through the fill valve or filling loop, following the manual. Close the valve or disconnect the filling loop once the reading is right. Check the gauge again after the system has run for a while, because the pressure changes as the water heats and cools.

When the air keeps coming back

If radiators go cold again within days or weeks, air is still getting in or water is being lost. Common causes include:

  • A slow leak at a radiator valve, fitting, or joint
  • Pressure that keeps falling, so you have to top up often
  • A fault with the expansion vessel, which can affect pressure
  • A fill valve or filling loop that isn’t fully closed

Repeated bleeding only treats the symptom, so it’s worth having the cause found.

When to call a professional

Call a licensed heating engineer or HVAC technician if:

  • The pressure won’t stay in range after topping up
  • You see water leaking from the boiler or pipework
  • The boiler shows an error code, shuts down, or won’t restart
  • Air is trapped in an underfloor system, a manifold, or a part you can’t reach
  • You’re unsure about any step, especially on a gas boiler

Bleeding the radiators and checking the pressure often clears a simple air problem. When it doesn’t, the cause is usually a leak or a fault that needs a professional to find and fix.