Quick answer
A typical split-system air conditioner has two main coils: an evaporator coil indoors and a condenser coil outdoors. Refrigerant moves between them. The evaporator absorbs heat from the indoor air, and the condenser releases that heat outside.
The evaporator coil
The evaporator coil sits indoors, usually in the air handler or on top of the furnace. Warm house air passes over the coil and gives up heat to the refrigerant inside the tubes, which is cold. The air cools and dries. Water that condenses on the coil drains away through a drain pan and drain line.
Because the coil stays cold and wet, it collects dust and can grow mold if it isn’t kept clean. Regular filter changes and periodic inspections help.
The condenser coil
The condenser coil sits outdoors in the condensing unit, which also holds the compressor and the outdoor fan. The fan pulls outdoor air across the coil. The heat the refrigerant picked up indoors is released into that air, so the condenser coil runs warm to hot. Its thin metal fins carry the heat away from the tubes.
Condenser coils come in different fin designs, and types of condenser coil fins covers the common ones.
How refrigerant links the two
The compressor pressurizes the refrigerant, and the hot gas flows to the condenser. There the refrigerant cools and condenses into a liquid. It then passes through a metering device, which lowers its pressure, and flows into the evaporator. In the evaporator, the refrigerant boils and absorbs heat. From there it returns to the compressor as a gas, and the loop starts again.
The refrigerant stays inside a sealed system and doesn’t need routine topping up. If a system seems low on refrigerant, that usually points to a leak, which a technician needs to find and repair. Owners sometimes ask, “How much does it cost to refill refrigerant in an AC unit?” Refilling without fixing the leak only postpones the problem.
How heat pumps swap the roles
A heat pump uses the same two kinds of coils, but a reversing valve changes which direction the refrigerant flows. In cooling mode, the indoor coil is the evaporator and the outdoor coil is the condenser. In heating mode, the roles swap: the indoor coil releases heat into the house, and the outdoor coil absorbs heat from the outside air.
“How does a heat pump work?” covers the full process, and heat pump vs split system compares the equipment types.
Coil construction
Coils are also described by how they are built. Fin-and-tube coils have round tubes with fins attached. Microchannel coils use flat tubes with many small channels. Condenser coils come in both styles, and the outdoor coil’s fin designs are covered in types of condenser coil fins.
Signs of trouble on each side
Outdoor coil: dirty or bent fins, debris packed against the coil, a unit that runs longer than usual, weak cooling on hot days, or an outdoor fan that won’t turn.
Indoor coil: weak airflow from the vents, ice on the indoor coil or refrigerant line, water leaks near the air handler, a musty smell, or warm air from the vents when the system should be cooling. Warm air from the vents has several possible causes, and “Why is my house air conditioner blowing hot air?” walks through them.
Caring for both coils
- Outdoor coil: keep it clean and clear of debris. Rinsing gently a few times a year is common, and the steps are covered in how to clean your air conditioner condenser unit.
- Indoor coil: change the filter regularly, keep the drain line clear, and have a technician check the coil during routine service.
- Refrigerant and sealed-system work: leave it to licensed technicians.