Blowing Warm Air

Why Is My House Air Conditioner Blowing Hot Air?

Home AC blowing hot air? Check the thermostat mode, outdoor unit, air filter, frozen coil and refrigerant. Learn what normal cool air feels like.

On this page
  1. Short answer
  2. What normal cool air feels like
  3. Check the thermostat
  4. Check the outdoor unit
  5. Replace or clean the air filter
  6. Look for a frozen coil
  7. Clean the outdoor coil
  8. Low refrigerant
  9. Ducts and airflow
  10. A heat pump may act differently
  11. When to call a technician

Short answer

Air from a working home air conditioner should feel clearly cooler than the air in the room. If it feels warm or close to room temperature, the usual causes are the thermostat set to the wrong mode, the outdoor unit not running, a dirty filter or frozen indoor coil, low refrigerant, or blocked airflow. Some of these you can check safely. Others need a technician.

If the unit is an evaporative cooler rather than a refrigerated system, the causes are different, and the pads and water supply are the place to look.

What normal cool air feels like

Cool air from a central or split system should be noticeably cooler than the air it is drawing from. A rough rule of thumb often used by technicians is a drop of around 15 to 20 degrees between return air and supply air. Treat that as an approximation rather than a precise test. What matters most is whether the air is clearly cooler and whether the house is getting cooler over time.

Check the thermostat

  • Mode: set it to cool, not heat or off.
  • Fan: set it to auto. On the fan setting, the blower runs even when cooling is off, so air can feel warm between cooling cycles.
  • Setpoint: set it below the current room temperature.
  • Display and power: if the screen is blank or the readings look wrong, check the batteries or the power to the thermostat.

Check the outdoor unit

The outdoor unit holds the compressor and the fan that moves heat outside.

  • When cooling is called for, listen for the fan and the compressor. If both are silent, check the breaker panel.
  • Check the disconnect switch near the outdoor unit, if there is one.
  • If a breaker trips again after you reset it, stop and call a technician rather than resetting it repeatedly.
  • Make sure nothing blocks the unit. Leaves, grass, debris and shrubs crowding the sides can restrict airflow.

Do not open the outdoor unit’s electrical panel or touch its wiring or capacitor. A capacitor can hold a charge even when the power is off. If the outdoor fan runs but spins the wrong way or does not turn, that can involve wiring or the motor, so leave it to a technician. Wondering what would cause a condenser fan motor to spin the wrong way? That question is best answered by someone who can test the circuit safely.

Replace or clean the air filter

A dirty filter restricts airflow across the indoor coil. Reduced airflow can make the coil run too cold and freeze, and the house will feel less cool as a result. Check the filter and replace it when it looks dirty or at the interval printed on the package. Also make sure supply vents and return grilles are open and not blocked by furniture or rugs.

Look for a frozen coil

Signs of a frozen indoor coil include ice or frost on the refrigerant lines or the indoor unit, water dripping near the air handler, and weak airflow from the vents. If you see ice:

  1. Turn cooling off at the thermostat.
  2. Set the fan to on so air keeps moving over the coil while the ice melts.
  3. Once the ice has cleared, check the filter and the vents.
  4. If the coil freezes again, call a technician.

Ice is usually a symptom of airflow or refrigerant trouble rather than the root cause. If you suspect the evaporator coil itself, a technician can check it along with the airflow, which is more reliable than guessing from the ice alone.

Clean the outdoor coil

A dirty outdoor coil can reduce cooling. With the power off at the disconnect, gently rinse the coil from the outside with a garden hose. Do not use a pressure washer, which can bend the fins.

Low refrigerant

Refrigerant is not used up in normal operation. If the system is low, it has a leak. Signs can include ice on the lines or coil, air that is only slightly cool, a hissing sound, or a system that runs for long periods without reaching the setpoint.

Low refrigerant needs a certified technician to find and repair the leak before the system is recharged. Recharging without fixing the leak is not a lasting solution. How much does it cost to refill refrigerant in an AC unit? The honest answer depends on the leak, so ask for a diagnosis before you agree to a top-up.

Ducts and airflow

Leaks in ductwork, especially in attics and crawl spaces, can pull cooled air out before it reaches the rooms. Blocked return grilles and closed supply vents also reduce airflow. Closing many vents at once can strain the system, so avoid shutting most of them.

A heat pump may act differently

If your system is a heat pump, it may blow air that feels less hot in heating mode, and it can blow cooler air for a few minutes during a defrost cycle. Check which mode the system is in before you assume it is faulty.

When to call a technician

Call a qualified technician if:

  • The breaker trips again after a reset, or you smell burning
  • Ice comes back after the coil has thawed
  • The outdoor unit does not run when cooling is called for
  • You suspect low refrigerant
  • The house still does not cool after the checks above

Some parts fail more often than others. What is the most common part to fail on an AC unit? The answer varies by model, so a technician’s diagnosis is more useful than a guess.

The complete guide to blowing warm air