The short answer
A whole house ventilation control is the switch, timer or sensor that tells the ventilation fan when to run and how fast. The fan and ductwork move the air. The control sets the schedule. Many homes use one simple control, and some combine several.
What the control is managing
Whole house ventilation is separate from the exhaust fans in a kitchen or bathroom, which usually serve a single room. A whole house system moves air through the entire home, using ducts that reach bedrooms and living spaces. Depending on the design, it may:
- Pull stale indoor air out (exhaust only)
- Push outdoor air in (supply only)
- Do both at once (balanced systems, which include heat recovery ventilators, or HRVs, and energy recovery ventilators, or ERVs)
A balanced system runs two fans, one for each direction, with a core that lets heat move from the outgoing air to the incoming air. An ERV also lets some moisture pass between the two airstreams. The control has to run both fans together so the house does not end up under too much pressure one way or the other.
Depending on the system, fresh air reaches the rooms through its own ducts or through the home’s existing HVAC ductwork. Ventilation also affects heating system efficiency, because air that leaves the house has to be replaced, and that replacement air has to be heated or cooled.
Common types of control
Manual switch
The simplest option is a wall switch or a fan speed selector. The fan runs only when someone turns it on. People forget, which is why many systems also have a timer or sensor.
Timer
A timer runs the fan for a set number of minutes each hour. This is a common way to get steady, low-level airflow without running the fan at high speed all day.
Humidity sensor
A humidistat measures indoor humidity and raises the fan speed when the reading rises above a set point. This can help after showers or during damp weather. In winter, a humidity-based control may run less, because ventilating with cold outdoor air tends to dry out indoor air. Dry winter air is a separate issue from ventilation, so it is worth weighing the furnace humidifier pros and cons on their own.
CO2 or occupancy sensors
Some controllers use indoor carbon dioxide (CO2) readings to decide when to ventilate more. CO2 tends to rise when several people are in the same room. These controls are more common in offices and schools than in homes.
Thermostat and smart controllers
Some systems connect to a thermostat or a smart home controller. The ventilation may run on a schedule, or whenever the heating or cooling system runs. Some are wired to the furnace or air handler blower. Ask your installer how yours is wired, since the answer changes how the system behaves.
How the control becomes airflow
The control sends a signal to the fan motor or motors. Many systems have at least two speeds: a low setting for steady background ventilation and a higher setting for a boost. During installation, the airflow for each speed is usually set by the installer. Changing the speed on the control changes the rate within the range the installer set.
Settings that matter
- Run time or speed. Start with the manufacturer’s or installer’s recommendation. Changing it changes how much fresh air the home gets.
- Humidity set point. A set point that is too low can make winter air very dry. A set point that is too high may let moisture build up before the fan responds.
- Boost. The boost setting is useful for cooking, showers and other moisture or odor sources. It is not meant to run all day.
Basic checks you can do
- Confirm the control shows the correct time, mode and humidity reading.
- Listen for the fan at each speed to make sure it responds.
- Keep the outdoor intake and exhaust hoods clear of snow, leaves and debris.
- Clean or replace filters on the schedule in your manual. Some systems have a filter on the fresh-air side as well as the exhaust side.
- If your unit has a condensate drain, make sure water drains freely.
When to call a technician
Call a qualified technician if:
- The fan does not run, runs at the wrong speed or does not respond to the control.
- The unit makes a new or unusual noise.
- Frost or ice builds up on the unit beyond what the manual describes.
- You see water or damp spots near the unit.
- You have fuel-burning appliances. Exhaust fans can change how those appliances vent, so a professional should check the setup.
A note on safety
A ventilation control does not detect carbon monoxide, and ventilation is not a replacement for carbon monoxide alarms. Keep working carbon monoxide alarms in the home, placed as the manufacturer directs.