What are the main components of a forced air furnace?
A forced air furnace has four main groups of parts. The airflow components move air through the house. The heating components make heat. The control and safety components decide when to run and shut down. The venting components carry exhaust outdoors. The exact parts depend on whether the furnace burns gas or uses electric elements, but most units include the core parts below.
Airflow components
- Return ducts and air filter. Air from the rooms returns through the ducts and passes through the filter, which catches dust before the air reaches the blower.
- Blower assembly. The motor and blower wheel push air through the furnace and into the supply ducts. Some furnaces use an ECM motor, which is a variable-speed type. Others use a simpler motor with fixed speed settings. If you are curious about the first type, see what is an ECM motor in a furnace.
- Supply plenum and ducts. The plenum is the box on top of or beside the furnace that collects warm air and feeds the supply ducts that run to each room.
Heating components
- Burners and gas valve (gas furnaces). The burners burn a controlled mix of gas and air. The gas valve controls how much gas reaches them.
- Heating elements (electric furnaces). These are resistance elements that warm up when electricity passes through them. Electric units do not have burners, a gas valve or a flue.
- Heat exchanger (gas furnaces). The heat exchanger carries heat from combustion into the air moving across it, while keeping combustion gases separate from the air in the house. For the details, read how does a heat exchanger work in a furnace.
Control and safety components
- Control board. The electronic controller that runs the startup sequence and reads the thermostat and safety switches.
- Thermostat. Sits in the living space and sends signals to the furnace to call for heat or fan.
- Transformer. Reduces household voltage to about 24 volts for the control circuit.
- Igniter. Lights the gas on most modern gas furnaces.
- Flame sensor. Confirms that the burners are lit. If no flame is detected, the control board shuts off the gas.
- Limit switch. Shuts the heat down if the furnace gets too hot, such as when airflow is blocked.
- Pressure switch and inducer motor. On many units, the inducer draws exhaust through the heat exchanger, and the pressure switch confirms the airflow is correct before the burners fire.
Venting and exhaust components
- Flue or vent pipe. Carries exhaust gases from a gas furnace to the outdoors.
- Condensate drain. Found on condensing furnaces. It removes water that forms when the exhaust cools.
Whether a unit is a non-condensing furnace or a condensing model changes its venting. Non-condensing units usually use metal venting, while condensing units use plastic pipe and have a drain.
Why the layout varies
Furnaces come in upflow, downflow and horizontal configurations, and each brand arranges parts a little differently. Efficiency level also matters. A high efficiency furnace vs standard furnace comparison usually shows the biggest differences in the heat exchanger design and the venting. Use the diagram on your own unit and the owner’s manual to confirm the exact layout.
When a part may be the problem
Symptoms overlap, so one part is not always the cause. A furnace that will not produce heat might have a dirty flame sensor, a failed igniter, a tripped limit switch, a fault in the control board, or a gas supply issue. Weak heat can come from a clogged filter, a blower problem or blocked ducts.
On electric furnaces, a failed heating element can be checked with the steps in how to test heating element in furnace. Still, testing gas components and live wiring should be done by a qualified technician. Diagnosis is safer and more accurate when a professional has the right tools and training.