What color wires go where on a furnace?
There is no universal color code for furnace wiring. Installers, manufacturers and the age of the system all affect which colors you will see. Thermostat wires often follow a common pattern, but treat color as a hint, not a rule. Confirm each wire by its terminal label, the wiring diagram inside the furnace panel, or the labels on the thermostat.
Common thermostat terminal letters and typical colors
These are the terminal letters you will most often see. The colors listed are typical, not guaranteed.
- R. 24-volt power from the furnace transformer. Often red. Some systems split this into Rh for heating power and Rc for cooling power.
- C. Common, which completes the control circuit. Often blue or black.
- W. Calls for heat. Often white.
- Y. Calls for cooling. Often yellow.
- G. Runs the fan. Often green.
- O or B. Used on heat pump systems to control the reversing valve. The color varies, and orange is common for O.
Some systems add extra terminals for a second stage of heat or cooling, such as W2 or Y2. Those wires follow the same logic, so check the labels.
Is the C wire always blue?
No. Blue is a common color for the C wire, but it is not guaranteed. An older or altered system may use a different color, or the C wire may be missing entirely. Many newer thermostats need a C wire to power their electronics, so a missing one can cause problems. Check the terminal the wire is connected to before assuming anything from its color.
Low-voltage control wires and line-voltage wires
Thermostat and control wiring is low voltage, typically 24 volts. It is thin and is not a serious shock hazard. A short, however, can damage the control board or the transformer.
The furnace’s power supply is different. In US homes, the main supply to a furnace is usually 120-volt or 240-volt house power, carried in heavier cable. Conductors in household wiring are often black, white, and green or bare copper, but that is a general pattern, not a rule for every furnace. Electric furnaces often run on 240-volt circuits, so do not assume the colors match what you expect.
Before you touch any wires
- Turn off the furnace at its service switch and at the breaker. Do not rely on the thermostat being off.
- Confirm the power is off with a non-contact voltage tester or a multimeter before you touch anything.
- Take photos of the existing wiring from several angles before disconnecting a single wire.
- Label each wire with its terminal letter before removing it. Painter’s tape and a marker work well.
- Do not reuse wires that are cracked, brittle or burned. Replace them, or call a technician.
If you see burn marks, melted insulation or a wire you cannot identify, stop and call a licensed HVAC technician or electrician.
Matching wires to terminals
Start with the wiring diagram on the inside of the furnace panel. Compare it to the labels on the thermostat and to the wires you labeled. Where the diagram and the labels disagree, trust the diagram that matches your exact model.
With the power on and the thermostat set to call for heat, a multimeter set to AC volts usually reads about 24 volts between R and C. If you see no reading, or something unexpected, do not keep testing. Turn the power off and get help. Wiring tests of this kind should be done only by someone who is trained to take readings safely.
Wire size is a separate question
Wire color and wire gauge are different things. If you are running new control cable, the gauge matters for the length of the run and the load. Gauge is covered in what size wire do you run to a furnace.
When to call a professional
Call a licensed HVAC technician or electrician if any of these apply:
- You are not sure which wire goes to which terminal.
- A wire is damaged, burned or loose at a terminal.
- The furnace has tripped breakers, or the control board has failed after a wiring change.
- Your work would involve line-voltage wiring.
For the broader picture of how the control side fits together, furnace wires explained covers the terminals, the transformer and common wiring setups. If you are wiring a thermostat yourself, how to wire up a 3 wire thermostat walks through the basic connections, but always check it against your own furnace’s diagram first.