The short answer
The most common ductwork installation problems are leaky joints, ducts sized by guesswork, crushed or sagging flexible duct, too few return paths, and uninsulated runs in attics or crawl spaces. Each one wastes energy, reduces airflow, or both. Most of them are easy to check for once you know what to look at.
Leaky joints
Duct joints that are not sealed let conditioned air escape into attics, crawl spaces or wall cavities. A common mistake is using standard cloth-backed duct tape. That tape does not hold up well on ductwork. Use mastic or tape rated for ducts, such as products listed to UL 181. Seal the seams, the joints between sections, and the connections at the registers and the equipment.
Ducts sized by guesswork
Rules of thumb can be a useful starting point, but a duct sized by eye may carry too little air to a distant room and too much to a nearby one. Sizing from airflow, the question of how do you calculate cfm for duct size, is where guesswork often shows up. Ask whether the sizes came from a load calculation and a layout, not just from what the installer usually does.
Crushed, kinked or sagging flexible duct
Flexible duct is quick to install and easy to damage. Runs that are stretched tight, bent sharply, crushed under joists or left sagging between supports all restrict airflow. Support flexible duct at regular intervals with wide straps, keep runs as straight as the space allows, and keep it clear of boxes and equipment.
Too few return paths
Supply air needs a way back to the equipment. When bedrooms have supply registers but no return, closed doors can trap air and raise pressure in the room. Undersized returns make the blower work harder and can cause noise. Transfer grilles, jump ducts or dedicated return ducts are common ways to give air a path back. The right choice depends on the house, so a designer should make that call.
Uninsulated runs in unconditioned spaces
Ducts that run through attics, crawl spaces or garages pick up heat or cold from those spaces. Insulation helps the air reach the room closer to its intended temperature, and it can help limit condensation on cold ducts.
Registers and filters that do not match the design
A register placed far from where air is needed can leave a room too warm or too cool, even when the ducts themselves are sound. A filter with much higher resistance than the system was designed for can reduce airflow in the same way.
Skipping a check after the work
A system can look finished and still run poorly. A static pressure and airflow check after installation shows whether the blower is moving the air it was designed to move. Compare the reading with the equipment’s rated range, and ask the installer for the results. The meaning of that number is explained in what is external static pressure in hvac.
Most of these problems are invisible once the walls are closed, so it is worth asking questions while the ducts are still open and accessible.