Testing Heating Elements

How to Tell If a Furnace Heating Element Is Bad

Learn the signs of a bad furnace heating element, how to rule out the breaker, limit switch and fuses first, and when a technician should take over.

On this page
  1. Short answer
  2. Common symptoms of a bad element
  3. Rule out the simple causes first
  4. The access-panel door switch
  5. Check the high-limit switch and fuses
  6. Inspect the element
  7. Test the element with a multimeter
  8. Reading the results
  9. Gas furnaces are different
  10. When to call a professional
  11. Summary

Short answer

In an electric furnace, a bad heating element usually shows up as no heat, or partial heat, while the blower keeps running. Before you blame the element, rule out the simpler causes: the thermostat, the breaker, the furnace’s power switch, a clogged filter, the access-panel door switch, the high-limit switch, the fuses, and the relay or sequencer that switches the strips on. Then inspect the element and test it with a multimeter.

If you’re not sure whether your unit is electric, how to know if furnace is gas or electric explains how to tell. This article covers electric furnaces only.

Common symptoms of a bad element

  • The blower runs, but the air from the vents is cool or only lukewarm
  • Some strips seem to work and others don’t, so the house heats unevenly
  • The furnace heats for a short time, then shuts off
  • A burning smell that doesn’t clear, or one that lingers after the first run of the season
  • A breaker that trips when the heat turns on

These symptoms can come from many parts, so they point you to the heat section, not to a single bad element. A blower that runs fine on its own is a separate part. What is an ECM motor in a furnace explains one common blower type. Whether a strip is energized is also a separate question from whether it works, and how to tell if heat strips are on or off covers that.

Rule out the simple causes first

Check these before you open the heat section:

  • Thermostat. Make sure it’s set to Heat, the setting is above room temperature, and the display shows that it’s calling for heat. Dead batteries or a faulty thermostat can mimic a furnace problem.
  • Breaker and power switch. Confirm the furnace breaker is on and the furnace’s service switch is on.
  • Air filter. A clogged filter restricts airflow and can trip the high-limit switch, which shuts off the heat.
  • Registers and returns. Make sure the supply and return registers are open and not blocked.

The access-panel door switch

Many furnaces have a door safety switch that cuts power to the heat and blower when the access panel is open. If you remove the panel and the furnace goes dead, that switch may be the reason. It’s a safety feature, so don’t bypass it. Checking a furnace with the panel off and the power on is a different job, and a technician should handle it.

Check the high-limit switch and fuses

The high-limit switch shuts off the heat if the furnace overheats. A dirty filter, blocked airflow or a blower fault is a more common reason for it to trip than a bad element. If it keeps tripping, find out why before resetting it again.

Fuses on the control board or in the heat section can also blow. A blown fuse can point to a shorted element or a wiring fault. Replacing the fuse without finding the cause may not last.

Inspect the element

Turn off the power at the breaker and confirm it’s off. Then remove the access panel and look for blisters, cracks, sagging coils, scorch marks or melted wiring. If you see scorched or melted wiring, stop and call a technician.

Test the element with a multimeter

With the power off and the element disconnected, check it for an open circuit and for a ground fault. Set the meter to ohms to see whether the element has a complete path, and to continuity to see whether it touches the metal frame. Then compare the ohms reading with the element’s rated resistance, which you can estimate with R = V² ÷ W. The step-by-step method is in how to test heating element in furnace.

Reading the results

  • Open circuit (OL or no reading). The element has likely burned out.
  • Continuity to the metal frame. The element is grounded and should be replaced.
  • Reading near the calculated value, no ground. The element is probably good. Look at the limit switch, fuses, relay and control parts.
  • Reading far below the calculated value. Possible internal short. Replace the element.

A meter test can’t show every fault, so a clean reading doesn’t rule out every problem.

Gas furnaces are different

A gas furnace has no heating elements. If a gas furnace won’t heat, the causes are different, and they include the burner, the igniter, the flame sensor and the gas supply. Gas problems carry fire and carbon monoxide risks, so have a qualified technician check them.

When to call a professional

  • The breaker trips when the heat runs
  • You find scorched or melted wiring
  • The high-limit switch keeps tripping
  • The element tests bad, and you need a matching replacement part
  • You aren’t comfortable working around 240-volt wiring

Summary

A bad heating element in an electric furnace usually shows up as no heat, or partial heat, with the blower still running. Rule out the thermostat, breaker, filter, limit switch and fuses first, then inspect and test the element. If the element fails the meter check, replace it or have a technician do it. If repair costs climb, what is the $5000 rule for furnace explains one common way to weigh repair against replacement.

The complete guide to testing heating elements

How to Test the Heating Element in a Furnace
Read the guide