Short answer
A grounded heating element is one where the live electrical part touches the metal sheath or the furnace frame. To check for it, turn off the power, disconnect the element, and test between each terminal and the metal with a multimeter set to continuity or the highest resistance range. A beep or a low reading means the element is grounded, and it should be replaced.
What a grounded element means
An electric heating element carries current through a resistance wire inside a metal sheath. Insulation inside the sheath keeps the wire from touching the metal. When that insulation breaks down, or the element is bent, cracked or pushed against the frame, current can flow from the wire into the metal. That’s a ground fault.
A grounded element matters for three reasons:
- The metal parts of the furnace can become energized, which creates a shock risk for anyone who touches the cabinet.
- Current leaking to ground often trips the breaker.
- A fault left alone can damage nearby wiring and lead to heat or arcing.
Safety before testing
Use the same precautions as for any furnace heat strip:
- Turn the thermostat to Off.
- Switch off the furnace’s power switch, if it has one, and turn off the breaker that feeds the furnace. Tape a note over it.
- Confirm the power is off with a non-contact voltage tester at the element terminals.
- Let the element cool before you handle it.
- Disconnect the element’s wires, and keep them away from metal while you test.
If you find power anywhere in the cabinet when it should be off, stop and call a technician. Don’t test a live furnace.
How to check with a multimeter
You’ll need a digital multimeter with a continuity setting and an ohms (Ω) range.
- Disconnect the element from the circuit. Readings taken with the wires still attached can be misleading.
- Set the meter to continuity, which usually beeps when a circuit is complete. If your meter has no continuity setting, use the highest resistance range.
- Put one probe on the furnace frame or on the element’s metal sheath, and the other probe on one element terminal.
- Repeat for the other terminal. Check each terminal separately.
- Read the results.
Reading the results
- No beep, OL, or a very high reading. No ground fault shows between that terminal and the metal. This is the expected result for a good element.
- A beep or a low reading. The element is touching metal and is grounded. Replace it.
- One terminal grounded and the other not. The element is still grounded and should be replaced.
A meter check is a quick test, not a full proof. An insulation resistance tester, sometimes called a megohmmeter, is more sensitive, and technicians often use one for this check. If you’re unsure after a clean meter reading, ask a technician to test it.
Other causes of repeated breaker trips
A grounded element isn’t the only reason a breaker trips. Check for these as well:
- A wire that has been pinched, chafed or pierced, so it touches the cabinet
- Moisture or debris inside the cabinet
- A breaker that is too small for the furnace’s load. Check what amp breaker does a furnace need against the rating label.
- Other grounded wiring in the heat section
What to do if the element is grounded
Replace the element. Don’t wrap it in tape, straighten it by force, or try to seal the fault. Once the insulation inside the sheath is damaged, the fault won’t reverse. Before installing the new element, find out what caused the ground fault, such as a bent element, a loose mount or a wire rubbing against metal, and fix that too.
Oven elements can ground out as well, and the same meter check applies. An oven element sits in a hot cavity, though, so let the oven cool fully and confirm the breaker is off before you test.
When to call a professional
Call a licensed technician if:
- The meter shows a ground fault and you’re not sure what caused it
- The breaker keeps tripping after you replace the element
- You see melted, scorched or loose wiring
- You need an insulation resistance test or a matching replacement part
- You aren’t comfortable working inside a 240-volt cabinet
If the furnace has stopped working altogether, electric furnace not working lists other common causes. Wire size is a separate question from the element itself, and what size wire do you run to a furnace covers that.
Summary
To check for a grounded heating element, turn the power off at the breaker, disconnect the element, and test each terminal against the metal frame or sheath with a multimeter. A beep or a low reading means the element is grounded. Replace it rather than putting it back into service.