Radiant Heating and Cooling

How Radiant Cooling and Heating Work

Radiant systems heat or cool a home through its floors, walls or ceilings instead of moving air. Here is how they work, their main parts and basic upkeep.

On this page
  1. What radiant heating and cooling are
  2. How water-based systems work
  3. Electric radiant systems
  4. Radiant cooling and condensation
  5. How quickly radiant systems respond
  6. Parts you may find in a system
  7. Basic upkeep
  8. Costs and efficiency
  9. Is it a good fit?

What radiant heating and cooling are

Radiant systems change the temperature of a home’s surfaces, usually its floors, walls or ceilings, rather than pushing conditioned air through the rooms. A warm surface gives off heat that reaches people and objects directly, and the room air warms as they do. A cool surface does the opposite and absorbs heat from the room.

Because the surfaces do most of the work, these systems move little air. Many people find the warmth feels more even, with fewer drafts and less air blowing dust around. How well that works depends on the home, the layout and how the system is set up.

How water-based systems work

Most radiant systems in homes are hydronic, meaning they circulate water through a closed loop of tubing. A heat source warms the water for heating or chills it for cooling. A pump moves the water through the tubing, which is usually cross-linked polyethylene, often called PEX. The tubing is set into a concrete slab, a thin layer above a subfloor, or panels in a ceiling.

Radiant floors generally run on lower water temperatures than a traditional radiator does, so the heat source needs to be able to supply water at the temperature the floor requires.

The heat source can be a boiler, a water heater set up for space heating, or a heat pump. Heat pumps are a common partner for radiant loops, and the heat pump system types differ in how they connect to the rest of the home.

Each zone, often a room or a group of rooms, has its own thermostat and its own valve or loop. A manifold, a set of valves and flow meters where the loops connect, lets the installer balance the flow between zones.

Electric radiant systems

Electric radiant systems use heating cables or mats placed under the floor covering, or heating panels in a ceiling or wall. They turn electricity into heat directly at the surface and have no water loop. They are most often used in bathrooms and other smaller spaces, or as an add-on to another heat source.

Because electric systems only add heat, they cannot cool a room.

Radiant cooling and condensation

Radiant cooling sends chilled water through the same kind of tubing or panels. The cool surfaces absorb heat from people, furniture and the air in the room.

The main limit is moisture. If a cooled surface drops below the dew point of the room air, water vapor condenses on it. Condensation can cause damage and mold, so radiant cooling systems use controls to keep surface temperatures above the dew point. Many designs also pair the radiant surfaces with a separate way to manage humidity, such as dedicated outdoor air ventilation or a dehumidifier.

Radiant cooling handles sensible heat well, which is the heat that changes the temperature of the air and surfaces. It does not remove moisture on its own. Sizing a system starts with the cooling load, the rate at which heat enters the home from sunlight, people, appliances and outdoor air.

How quickly radiant systems respond

Radiant systems respond slowly. A concrete slab or other thick floor holds a lot of heat, so it takes time to warm or cool down. Many homes keep radiant heat running steadily rather than switching it on and off, and a large temperature setback overnight can take a long time to recover from.

This is why radiant systems tend to suit homes that stay at a fairly steady temperature better than homes where people want quick changes.

Parts you may find in a system

  • A heat source, such as a boiler, water heater or heat pump
  • A circulating pump and zone valves
  • A manifold where the loops connect
  • The tubing, and the floor, wall or ceiling it sits in
  • A thermostat for each zone
  • On hydronic systems, an expansion tank, a pressure gauge and an air vent or air separator
  • On cooling systems, sensors that help control condensation

Basic upkeep

  • Check the pressure gauge on hydronic systems. Most manufacturers list a normal range. A pressure that keeps dropping often points to a leak, and a technician should look at it.
  • Remove trapped air. Air in the loop can cause cold spots, gurgling and poor heat output. The steps are covered in how to get air out of boiler heating system.
  • Have the heat source serviced by a qualified technician, usually once a year.
  • Keep access to the manifold, valves and thermostats clear.
  • Keep a working carbon monoxide alarm in the home if you have a gas-fired boiler or furnace.
  • Leave gas, electrical and refrigerant work to licensed professionals.
  • For cooling, confirm the condensation controls and sensors are working, and watch for water stains or a musty smell near floors and ceilings.

Costs and efficiency

Radiant systems can cost more to install than a basic forced-air system, especially when tubing has to go into existing floors or ceilings. Costs depend on the size of the area, the layout and the heat source. Hydronic radiant floor heating cost varies widely for these reasons.

Efficiency depends mostly on the heat source, since the radiant surfaces only deliver heat that the source provides. Heating system efficiency ratings are a useful way to compare heat sources.

A radiant ceiling heating system works on the same principle, with the ceiling as the warm surface. It suits some rooms better than others, and the room’s layout and furniture matter.

Is it a good fit?

Radiant systems suit many homes well, particularly where comfort and quiet are priorities and floors or ceilings are already open for work. For other homes, a forced-air or heat pump system may fit better. A qualified HVAC professional can compare the options using the home’s size, layout and climate.

Keep exploring

Guides from other topics

All topics →