Signs of an airlock in a heating system include a cold top on a radiator, gurgling pipes, and uneven heat. Learn how to tell an airlock from other problems.

On this page
  1. What an airlock is
  2. Common signs of an airlock
  3. How to check a unit safely
  4. Airlock or something else?
  5. What to do if it is air
  6. When it is not air
  7. When to call a technician

What an airlock is

An airlock is a pocket of air that keeps hot water from flowing through part of a heating system. In a hot water radiator or baseboard unit, the air collects at the highest point, so that part stays cool while the rest of the unit warms up.

Common signs of an airlock

  • The top of the unit is cool and the bottom is warm.
  • You hear gurgling, knocking, or banging when the system runs.
  • One unit or one room heats more slowly than the rest.
  • The unit warms up after you bleed air from it.
  • The pipe feeding the unit is hot, but the unit itself stays cool. This can also mean a closed valve, so check the pattern below.

How to check a unit safely

Wait until the system has run for a while, then carefully move the back of your hand along the unit from one end to the other. Hot water units can burn, so do not press your skin against them. Look at the pattern:

  • Warm bottom, cool top: Air is the most likely cause.
  • Cool all over, with a hot pipe feeding it: The valve on the unit may be closed or stuck, or debris may be blocking the flow.
  • Cool all over, with cool pipes: The problem is more likely the boiler or the thermostat than an airlock.

Look at the valve on the unit as well. A closed valve, or a thermostatic head that is stuck, can make a unit run cold all over.

Airlock or something else?

Air is one of the common problems with hot water baseboard heating, but it is not the only one. Sludge (rust and debris in the water), a failed circulator pump, low boiler pressure, and a closed valve can all make a unit run cool. The boiler may also shut down on low pressure, so check the gauge before you assume the cause is air.

What to do if it is air

If the unit is cool at the top and warm at the bottom, bleed it. For the steps, follow a guide on how to bleed air from a heating system, and check the boiler pressure afterward.

When it is not air

If bleeding does not help, or the unit is cool with a warm pipe feeding it, stop opening valves and look at the wider system. Air that keeps coming back after bleeding often points to a leak, a failing air vent, or a problem on the boiler side. Those are jobs for a technician.

When to call a technician

Call a technician if an airlock keeps coming back, the boiler pressure keeps dropping, the boiler shuts off, or a unit stays cold after you have checked the valve and bled the air.