Cooling Load

What Is Cooling Load?

Cooling load is the heat that must be removed from a building each hour to keep it at a set temperature, measured in Btu per hour or tons.

On this page
  1. Cooling load in plain terms
  2. Load is not the same as capacity
  3. What makes up the load
  4. Sensible and latent load
  5. How the load is used
  6. Reading the number

Cooling load in plain terms

Cooling load is the rate at which heat enters a building and must be removed to keep its air at a set temperature. In a home, it is expressed in British thermal units per hour, written as Btu/h. The figure changes through the day with the weather, the sun and how the house is used.

Load is not the same as capacity

Capacity is what an air conditioner can remove. Load is what the house needs removed. A system should have capacity that matches the load on a hot design day, which is a demanding but typical hot day for the area. A system with much less capacity than the load will struggle. A system with much more can short cycle and handle humidity poorly.

What makes up the load

Heat comes into a home from several places:

  • Walls, roof and floors, through the materials and insulation
  • Windows, through sunlight and conduction
  • Air leakage through gaps around doors, windows and other openings
  • People, lights and appliances
  • Fresh air brought in by ventilation
  • Ducts that run through hot, unconditioned spaces

Sensible and latent load

The sensible part of the load is the heat that changes the air temperature. The latent part is the moisture the system must remove from the air. Both are handled by the air conditioner, and the latent part matters most in humid climates.

How the load is used

The cooling load is the starting point for choosing equipment. It guides how big a system should be and how the ducts are designed. The same idea connects to what is btu in hvac, which explains how capacity is rated on equipment.

Because the load is a calculated figure for a set of conditions, it describes a hot day rather than every moment of the year. On a mild day, the same house needs much less cooling. That is one reason a home can run its system for long periods on hot days and only briefly on cooler ones.

Reading the number

When you see a cooling load in Btu per hour, you can compare it with a unit’s rated capacity. A value of 12,000 Btu per hour equals one ton of cooling, which is covered in how many btu is 1 ton ac. A load calculation gives a number for each room or zone, so the total for the house is the sum of those parts, not a single guess.