Pellet Stoves

How Much Does It Cost to Run a Heat Pump for 1 Hour?

Find out how much a heat pump costs to run for one hour. Learn the formula, how to read your electricity rate, and why backup heat can change the figure.

On this page
  1. The short answer
  2. The formula
  3. Finding the power draw
  4. Finding your electricity price
  5. Measuring what the heat pump actually uses
  6. Why the hourly cost changes
  7. Backup heat costs more per hour
  8. A worked example
  9. Common mistakes
  10. Ways to keep the hourly cost down
  11. Bottom line

The short answer

For most homes, you can estimate the cost of one hour of heat pump operation by multiplying the unit’s power draw in kilowatts (kW) by your electricity price per kilowatt-hour (kWh). For illustration, a heat pump that draws 2 kW at 16 cents per kWh would cost about 32 cents for that hour. The real figure depends on the outdoor temperature, your thermostat settings, the size of the system and whether backup heat turns on.

The formula

Cost per hour = power draw (kW) × electricity price per kWh

Running for two hours doubles the figure, and running for eight hours multiplies it by eight. The hard part is finding the two inputs.

Finding the power draw

The nameplate on the outdoor unit lists electrical ratings, including minimum circuit ampacity (MCA) and maximum overcurrent protection (MOCP). These are design limits. They show the largest current the unit is built to use, not what it draws on a typical day. To get a rough upper limit, multiply the volts by the amps and divide by 1,000 to get kilowatts. Most whole-house heat pumps run on 240 volts. Treat the result as a ceiling, not an average.

Finding your electricity price

Your bill shows how many kWh you used and what you paid. Divide the energy charges, not fixed monthly fees, by the kWh used to get an average price per kWh. If your utility uses time-of-use pricing, the price changes through the day, so use the rate for the hours the heat pump usually runs.

Measuring what the heat pump actually uses

A measurement is more useful than a nameplate. Options include:

  • Utility smart meter data. Some utilities provide hourly usage through an app or online account. Compare it with the times the heat pump ran.
  • A whole-house energy monitor. An electrician can install a monitor that tracks the heat pump’s circuit.

A plug-in energy monitor will not work for most whole-house heat pumps, because they are hardwired to 240-volt circuits. Work inside the electrical panel or at the disconnect should be done by a licensed electrician.

Why the hourly cost changes

  • Outdoor temperature. As it gets colder, a heat pump gives less heat for each kWh it uses. Its power draw and its efficiency both change, so the same hour can cost more or less depending on the weather.
  • Defrost cycles. In cold, damp weather, the unit periodically reverses to melt frost off the outdoor coil. That uses energy and pauses heating.
  • Indoor fan. The blower in the indoor air handler also draws power, and it may run continuously on some settings.
  • Thermostat settings. Large temperature swings can cause the system to run backup heat to catch up. Many systems do this automatically.
  • System size and age. Larger and older units can draw more power for the same job.

Backup heat costs more per hour

Electric strip heating, the backup heat in many heat pump systems, works by electric resistance. It delivers about 3,412 BTU of heat for each kWh, which is the least efficient way the system makes heat. A heat pump’s compressor usually delivers more than one kWh of heat for each kWh of electricity, though the ratio drops in cold weather. Strip heaters in residential systems often draw several kilowatts, sometimes more than 10, so a single hour on backup heat can cost several times as much as an hour of normal heat pump operation.

Heat output differs as well, so the hourly bill alone is not a fair comparison with another heating system. Compare cost per unit of heat delivered when you weigh options.

A worked example

These numbers are illustrations, not measurements from a specific unit. Suppose the heat pump draws 2 kW and electricity costs $0.16 per kWh.

  • One hour: 2 kW × $0.16 = $0.32
  • Eight hours: 8 × $0.32 = $2.56

Now suppose the system runs one hour on backup strips that draw 10 kW at the same rate. That hour costs $1.60, and it also delivers a different amount of heat. The point is to know which hours the system is using and why.

Common mistakes

  • Using the nameplate maximum as if it were the typical draw.
  • Dividing the whole bill, including fixed charges, by kWh.
  • Forgetting the indoor fan and backup heat.
  • Turning a monthly bill into an hourly rate without checking how many hours the system ran.
  • Comparing the hourly cost of a heat pump with another system without converting to heat delivered.

If you are asking “why is my electric bill so high with a heat pump?”, the hourly math is a good first check. It shows whether the compressor, the fan or backup heat is the main load.

Ways to keep the hourly cost down

  • Keep filters clean and make sure the outdoor coil is clear of leaves and debris.
  • Avoid large thermostat setbacks that trigger backup heat. Ask your installer how your model handles setback and recovery.
  • Have the system serviced on the schedule the manufacturer recommends, so it runs as designed.
  • Seal air leaks and check insulation, since a house that loses less heat needs less run time.

Bottom line

The cost of one hour of heat pump operation is the unit’s power draw in kW multiplied by your electricity rate per kWh. Get the rate from your bill and the draw from a measurement, not just the nameplate. Keep in mind that cold weather and backup heat change the result, and compare heating options by cost per unit of heat, not by the hourly bill alone.