What electric strip heating is
Electric strip heating, also called electric resistance heat, warms air with electricity. A set of metal heating elements, often called heat strips, sits in the path of the air moving through a furnace or air handler. When the system calls for heat, electricity passes through the elements and they get hot. The blower pushes room air across them and into the ducts.
The idea is similar to the coil in a toaster, arranged so that moving air carries the heat away.
Strip heating shows up in two common ways in homes. An electric furnace uses strips as its main source of heat. A heat pump system often uses strips as a backup or supplemental source. Many homeowners ask, are heat strips necessary with a heat pump? That question depends on climate and system design, and it has its own answer.
How the heating elements make heat
Electric resistance heating works because the metal in the elements resists the flow of current. That resistance turns electricity into heat. Nearly all the electricity an element uses becomes heat in the space it heats, which is why resistance heat is often described as close to 100 percent efficient at the point of use.
Efficiency at the point of use is only part of the cost picture. In many areas, electricity costs more per unit of energy than natural gas. A heat pump can also deliver more heat per unit of electricity than a resistance element, especially in milder weather.
Heat strips are usually rated in kilowatts (kW). A system may have several strips, and their combined rating sets how much heat the strips can produce at full output. The rating is printed on the strip or the unit’s label.
How the thermostat and controls bring the strips on
The thermostat decides when heat is needed. In a heat pump system, the thermostat calls for the heat pump first. Strips come on only if the heat pump cannot keep up or if the thermostat is set to emergency heat.
In an electric furnace, the thermostat calls for heat and the control board brings the strips on. Strips are often switched in stages, so they do not all turn on at once. Each stage is connected to power by a relay or a contactor, which is a heavy-duty switch.
Emergency heat is a setting on many thermostats. It turns off the heat pump and runs only the strips. It is useful if the heat pump fails, but it uses more electricity than normal heat pump operation.
The blower must run while the strips are on. Moving air carries the heat away from the elements and keeps them from overheating.
Safety devices built into the system
Several devices protect the equipment:
- High-limit switch. A temperature switch in the air path shuts off the strips if the air gets too hot. Common causes include a dirty filter, a blower problem or closed supply registers. Some high-limit switches reset on their own, and some need a manual reset.
- Fuses or breakers. Some strip assemblies have fuses, and the main supply to the unit is protected by a breaker.
A high-limit switch that trips often is a sign that something is restricting airflow or failing. Resetting it without finding the cause does not fix the problem.
Strips draw a lot of current. They usually need a dedicated circuit, sized by an electrician or installer to match the equipment’s label. Do not use a power strip or extension cord for any heating equipment. People often ask, is it okay to plug a heater into a power strip? For a portable heater, the answer is no, and the same caution applies here.
Keeping electric strip heating in good shape
Routine care helps the strips last and keeps them safe.
- Turn off power before any inspection. Use the unit’s service switch and the breaker. Wait for the elements to cool before touching them.
- Change or clean the filter on the schedule the manufacturer lists. Restricted airflow is one of the most common causes of high-limit trips.
- Keep registers open and unblocked so air can move freely through the system.
- Expect a short burning smell at the start of the season. Dust that settles on the elements can burn off when the strips first turn on. The smell should fade within a short time. If it lasts, or smells like hot plastic or electrical wiring, turn the system off and call a professional.
- Schedule a yearly check with a qualified technician. A technician typically looks at the connections, contactors, control board, high-limit switch and the condition of the elements, and can measure the current each strip draws.
When to call a technician
Call a qualified technician if you notice any of these:
- A burning smell that does not fade, or a smell like electrical wiring
- A breaker that trips repeatedly
- Scorch marks, discolored wiring or a cabinet that runs hotter than usual
- One strip, or part of the heat, not working
- Strips that stay on after the thermostat is satisfied
- A high-limit switch that keeps tripping
Electric strip heating is simple in concept. Resistance makes the heat, and the controls decide when and how much. Most problems come down to airflow, controls or wiring, so a clear check of those three areas is a good place to start.