System Will Not Shut Off

Is Your Outside AC Unit Supposed to Shut Off?

Your outside AC unit should cycle off between cooling runs and stay off when the thermostat is off. Here's what normal looks like and when to worry.

On this page
  1. Short answer
  2. How the outside unit gets its signal
  3. What normal on-and-off running looks like
  4. When the outside unit should not be running
  5. Simple checks
  6. When to call a technician

Short answer

Yes. The outside unit, also called the condenser, should shut off between cooling cycles. It runs when the thermostat calls for cooling, stops once the house reaches the set temperature, and starts again when the house warms up. It should also stay off when the thermostat is turned off.

It is normal for the unit to run for long stretches on hot days. What is not normal is a unit that keeps running when cooling is switched off.

How the outside unit gets its signal

The thermostat does not usually power the outside unit directly. It sends a low-voltage signal to the indoor control board, which switches the outdoor unit on through a contactor. The contactor is an electrical switch that connects power to the compressor and the outdoor fan. When the thermostat stops calling for cooling, the signal ends, the contactor opens and the unit stops.

Because the signal passes through several parts, a fault in any of them can keep the unit running. The thermostat, the control board, the contactor and the wiring are the usual suspects. The thermostat side of this is covered by “why won’t my thermostat turn off my ac.”

What normal on-and-off running looks like

On a mild day, the unit may run in short bursts. On a hot afternoon, it may run for long periods without stopping. Both can be normal, as long as the unit shuts off when the house reaches the set temperature or when you turn cooling off.

Most systems also wait a few minutes before restarting after a stop. If you see the unit stop and start again, that alone is not a fault.

Long run times on a hot day raise a separate question. The guide to “is it normal for ac to run 20 hours a day” looks at when run time is a sign of a problem.

When the outside unit should not be running

Be concerned if:

  • The unit runs while the thermostat is set to Off.
  • The unit keeps running after you turn cooling off, and does not stop.
  • The unit runs in cold weather, when you have not asked for heating, and the system is not a heat pump.
  • You see ice on the copper lines or on the indoor coil. Ice can come from restricted airflow or low refrigerant, and the unit may keep running in a way that makes the problem worse.

Simple checks

  • Confirm the thermostat is set to Cool or Off as you intend, and that the set temperature is set correctly for the room.
  • Make sure nothing is blocking the outside unit. Keep leaves, grass and debris clear, and leave space around the cabinet.
  • Check the air filter. A dirty filter reduces airflow and can make the system run longer than it should.
  • If the coil looks dirty, switch the unit off at the disconnect and rinse the fins gently from outside with a garden hose at low pressure. The steps to clean your air conditioner condenser unit are a good starting point.

When to call a technician

Call a qualified technician if the unit runs when it should be off, will not stop after you switch the thermostat off, trips the breaker or makes new grinding or banging sounds.

Before any service, switch the system off at the thermostat and at the outside disconnect or breaker. Stay away from the electrical parts. Capacitors and other components can hold a charge and carry high voltage even when the system is off.

The complete guide to system will not shut off

Why Your HVAC Is Running When Turned Off
Read the guide

Keep exploring

Guides from other topics