The short answer
A full cooling load calculation is done room by room, using a method such as ACCA Manual J. You can make a rough estimate yourself. That is useful for planning and for checking a contractor’s numbers, but it is not a substitute for a proper calculation. The steps below cover the rough version.
Step 1: Measure the space
Measure the floor area of each room, which is its length times its width, and note the ceiling height. For a whole house, add the rooms together. Count the windows and doors, their sizes, and which direction each window faces.
Step 2: List the heat sources
Work through the main sources:
- Walls, ceilings and floors, especially any that face the sun or sit above an attic or crawl space
- Windows and doors
- Air leakage around openings
- People, lights, cooking and electronics
- Fresh air brought in by ventilation
Step 3: Estimate each part
Engineers estimate the heat flow through a surface as its U-factor, which describes how easily heat passes through it, times its area, times the temperature difference between inside and outside. The U-factor depends on the materials and insulation, which are hard to know without plans. Many homeowners use a simpler per-area factor instead and then adjust for windows and sun exposure.
Step 4: Add the parts together
Total the estimates for each room, then add the heat from people and equipment and the load from fresh air. Avoid piling on large safety margins. An oversized system brings its own problems, including short cycling and poor humidity control.
Step 5: Convert the total
Convert the total to Btu per hour. To get tons, divide by 12,000. For ton and Btu conversions, see how many btu is 1 ton ac.
A worked example
Take a 150 square foot room and apply a rough factor of 20 Btu per hour per square foot. That gives 3,000 Btu per hour. This is only an illustration. A room with a large sun-facing window needs more, and a shaded, well insulated room may need less.
When to stop and call a professional
A do-it-yourself estimate can be far off, especially for a whole house. Ask for a Manual J calculation before you buy a system or replace one. The basic steps for a whole-house figure are covered in how to size btu for a house, but the final answer should come from a room-by-room calculation done by a licensed HVAC contractor.