The short answer
A through-the-wall air conditioner removes heat from indoor air and releases it outside. It does this with a refrigerant cycle. The refrigerant absorbs heat as it evaporates indoors and gives up heat as it condenses outdoors. The unit does not make cold air. It moves heat from one side of the wall to the other.
The main parts
- Compressor: squeezes the refrigerant vapor, raising its pressure and temperature, and pushes it around the loop.
- Indoor coil (evaporator): the cold refrigerant inside absorbs heat from the room air passing over it.
- Outdoor coil (condenser): the hot refrigerant releases its heat into the outdoor air passing over it.
- Expansion device: a small metering device, such as a capillary tube or valve, that drops the refrigerant’s pressure before it reaches the indoor coil.
- Indoor and outdoor fans: the indoor fan pushes room air over the indoor coil, and the outdoor fan pulls outside air across the outdoor coil.
- Filter and drain: the filter catches dust before it reaches the indoor coil, and the drain carries away condensed water.
Step by step
- The indoor fan pulls warm room air through the filter.
- The air passes over the indoor coil. The refrigerant inside is cold, so it absorbs heat, and the air leaves cooler.
- As the refrigerant absorbs heat, it evaporates into a low-pressure vapor. Moisture in the air condenses on the cold coil and drains off as water.
- The compressor draws in the vapor and compresses it, which raises its temperature and pressure.
- The hot refrigerant flows to the outdoor coil. The outdoor fan blows outside air across it, and the refrigerant releases its heat and condenses back into a liquid.
- The liquid passes through the expansion device, which drops its pressure and temperature, and then returns to the indoor coil to repeat the cycle.
Why the air feels drier
As indoor air passes over the cold coil, some of its moisture condenses. That is why cooled air feels less humid. The collected water drains outside through a drain line, or in some models it is evaporated onto the hot outdoor coil. A drain that is blocked or set at the wrong slope can leak water, which is one reason the sleeve’s slope matters.
Heating and other settings
Some units add heat in one of two ways. A reversing valve lets the cycle run in reverse, as in a heat pump, or electric heat strips warm the air directly. Heat pump models move heat rather than generating it, so their heating output usually drops in very cold weather. For the reverse cycle in more detail, see how does a heat pump work.
Many units also have a dry setting that runs the cooling cycle to remove moisture, and a fan-only setting that runs the indoor fan without cooling. The differences are covered in air conditioner cool vs dry and what is fan only mode on air conditioner.
Air and ventilation
The unit draws room air in through the grille, cools and dries it, and pushes it back out. Because it recirculates indoor air, it does not bring in much fresh air. A room that needs fresh air will need a separate ventilation source.
Capacity and sizing
Cooling capacity is listed in BTU per hour. A unit that is too small runs for long periods and still struggles on hot days. A unit that is too large cycles on and off often, which can leave the air feeling damp. For a plain explanation of the number, see what is btu in hvac.
Why it helps to know how it works
Knowing the cycle helps you spot problems. A unit that runs but blows warm air, drips inside or cycles constantly may point to airflow, drainage, refrigerant or electrical issues, and each calls for a different fix. Refrigerant and electrical work should go to a qualified technician.