Wall and Window Unit Fixes

Why Is My AC Set to 72 but Reads 78?

Your AC is set to 72 but the display reads 78? Learn why the reading can differ from the setting, how sensor location plays a part, and how to check it.

On this page
  1. The set point and the room reading are not the same thing
  2. Why the display can read warm
  3. Cooling takes time
  4. Causes that keep the room from reaching the set point
  5. How to check the reading with a separate thermometer
  6. What to do next
  7. When a warm reading points to a problem

The set point and the room reading are not the same thing

The number you set on an AC is a target. The number on the display is the temperature the thermostat measures at its own location. The unit runs until that sensor reaches the set point, so the two numbers can differ for a while.

A set point of 72 with a display of 78 is not automatically a fault. It usually means the air at the sensor has not reached the target yet.

Why the display can read warm

On many window and wall units, the thermostat sensor sits near the air intake. It reads the air close to the unit, which can be warmer or cooler than the rest of the room. Sunlight through a window, a lamp, a television or a nearby oven can push the reading up. A sensor on a wall that gets afternoon sun can read warmer than the center of the room.

If the unit has a separate wall thermostat, the sensor is in that thermostat instead, and its position matters just as much.

Cooling takes time

A room does not drop several degrees the moment the unit starts. How quickly it cools depends on how hot the room is, how well it is insulated, how much sun comes through the windows, and how many people, lights and appliances are adding heat. After a hot day, walls and furniture hold heat that the unit also has to remove.

Because of all that, the question of how long should it take to cool a house from 90 to 72 has no single answer. Compare your room with itself over a few days instead.

Lowering the set point does not make the unit cool faster. The unit cools at its own rate, and the set point only tells it when to stop. Setting it lower just makes the unit run longer before it stops.

Causes that keep the room from reaching the set point

If the room stays well above the set point even after time has passed, something may be limiting the unit:

  • Dirty filter or coil. Less air crossing the coil means less heat removed.
  • Blocked airflow. Furniture in front of the grille, or debris and plants on the outdoor side, cut the airflow.
  • Air leaks. Warm air can come in around the sleeve, the window seal or gaps at the edges.
  • Too little capacity. A unit that is too small for the room runs nearly constantly and still falls behind on hot days. A unit that is much larger than the room can switch on and off too often and not remove much humidity.
  • Wrong mode. Fan-only and dry modes do not cool the way cool mode does.
  • Low refrigerant. This points to a leak and needs a licensed technician.

The full list of checks, in order, is in wall unit air conditioner not cooling.

How to check the reading with a separate thermometer

A simple thermometer is the best way to tell whether the display is accurate.

  1. Place it in the middle of the room, roughly at head height. Keep it away from the unit, windows, lamps and direct sun.
  2. Set the unit to cool, at the set point you want.
  3. Close doors and blinds, and avoid cooking or running other heat sources during the test.
  4. Compare the thermometer with the display after an hour or so.

If the thermometer reads close to the set point while the display reads warmer, the sensor location is the likely reason. If both stay warm, the unit is not keeping up, and the causes above are worth checking.

What to do next

  • Clean or replace the filter, and clear the grille and the outdoor side.
  • Check the sleeve or window seal for gaps and drafts.
  • Close blinds during the hottest part of the day, and keep heat sources away from the sensor.
  • Pick a set point you can reach comfortably. For guidance, see what temperature should an air conditioner be at.

If the room will not get below 80 even after these checks, the causes in ac not cooling below 80 are worth reviewing.

When a warm reading points to a problem

Have the unit checked if:

  • the room stays well above the set point on a mild day,
  • the unit switches on and off in quick bursts,
  • ice forms on the coil,
  • the air from the unit feels barely cool even when the room has had time to cool, or
  • the thermometer and the display disagree across several tests, and the sensor is not in a bad spot.

The complete guide to wall and window unit fixes

Wall Unit Air Conditioner Not Cooling: Causes and Fixes
Read the guide

Keep exploring

Guides from other topics

All topics →