Furnace Configurations

Manifold Pressure for Single Stage Natural Gas Appliances

A common manifold pressure for natural gas appliances is 3.5 inches of water column. Learn what the number means and why only a technician should adjust it.

On this page
  1. The usual answer: about 3.5 inches of water column
  2. What manifold pressure is
  3. Why it matters
  4. Single-stage versus higher-stage units
  5. Natural gas versus propane
  6. How it is checked and adjusted
  7. Safety first

The usual answer: about 3.5 inches of water column

Many single-stage residential natural gas appliances, including many furnaces, are set at a manifold pressure of about 3.5 inches of water column (in. w.c.). That is a common value, not a universal one. The exact setting is chosen by the manufacturer and printed on the rating plate or in the installation manual, and those documents govern for the specific unit.

What manifold pressure is

Gas reaches an appliance at a higher supply pressure. The gas valve reduces that pressure to the manifold pressure, which is the pressure in the pipe that feeds the burners. The manifold pressure, together with the burner orifices, sets how much gas flows at the firing rate the appliance is designed for.

Technicians measure it in inches of water column with a manometer, a gauge connected to a pressure tap on the gas valve.

Why it matters

Gas and air have to mix in the right ratio for a clean, complete flame. If the manifold pressure is too high or too low, the burner may:

  • Burn incompletely, which can produce carbon monoxide.
  • Show a yellow or flickering flame, or leave soot.
  • Heat poorly or cycle on and off more than it should.
  • Run hot enough to stress parts and trigger safety shutoffs.

Single-stage versus higher-stage units

A single-stage appliance runs at one firing rate, so it has one manifold setting for that output. Two-stage appliances have a low and a high firing rate, and their specifications give a setting for each. A modulating gas furnace has many firing rates, so its settings are given for several points or as a range. Always use the figures for the specific model.

Natural gas versus propane

Propane appliances run at a higher manifold pressure, commonly around 10 to 11 inches of water column, and they use different burner orifices. A natural gas appliance cannot simply be switched to propane or the reverse. Converting it requires the manufacturer’s conversion procedure, and the numbers are not interchangeable.

How it is checked and adjusted

A technician connects a manometer to the pressure tap on the gas valve, runs the appliance, and compares the reading with the rating plate. Adjustment is made at the gas valve, and only a qualified technician should do it. If the reading does not match the plate, the cause should be found, whether it is the regulator, the orifices or the gas supply pressure. Adjusting by guesswork is not a safe fix.

Safety first

If you smell gas, leave the home and call your gas utility from outside. Do not operate light switches or appliances while you smell gas. Keep a working carbon monoxide alarm near sleeping areas, and have the gas appliance inspected on a regular schedule.

The complete guide to furnace configurations