Installing Portable AC

Where to Put the Hose for Portable AC Continuous Drainage

Where to put a portable air conditioner's drain hose for continuous drainage, how to keep it downhill and kink-free, and how to spot a routing problem.

On this page
  1. Exhaust hose and drain hose are different
  2. Check whether your unit supports continuous drainage
  3. Where the drain hose should end
  4. Routing the hose without kinks or low spots
  5. Signs the drain hose is in the wrong place
  6. Single hose or dual hose

A portable air conditioner has two hoses that are easy to mix up. The exhaust hose carries hot air out through the window kit, and the unit needs it to work. The drain hose is optional. It carries condensation away from the unit if your model supports continuous drainage. Where the drain hose should end depends on where the water can flow downhill to, which is usually a floor drain, a suitable container or the outdoors.

Exhaust hose and drain hose are different

The exhaust hose runs from the unit to the opening in the window kit. It moves heat outside and has nothing to do with drainage.

The drain hose, if your unit uses one, connects to a drain outlet on the unit, usually near the bottom or the back. The manual shows where the outlet is. Some manuals call this a condensate hose. Keep the drain hose away from the exhaust hose so the two do not tangle or pull on each other.

Check whether your unit supports continuous drainage

Many portable units collect water in an internal tank, and you empty it by hand. Some units shut off when that tank is full, so you may need to empty it often in humid weather.

Units with a drain outlet let you attach a hose for continuous drainage. Some models need a drain plug removed or a cap fitted before the hose will seal properly. Some units behave differently when a drain hose is attached, so check the manual before you connect one.

Where the drain hose should end

Choose an end point that is lower than the unit’s drain outlet, so the water flows by gravity. Good options include:

  • A floor drain, if your home has one and the manual allows it
  • A suitable container placed on the floor, emptied regularly
  • Outside, through a path that slopes downward the whole way

Keep the end out of standing water, and do not place it where it could be pinched by a door or the window. Keep it away from electrical outlets and cords as well.

Routing the hose without kinks or low spots

Keep the path short and straight. Any loop that rises above the outlet, or any low dip where water can sit, can stop the water from flowing. Secure the hose with clips or tape if needed, but do not clamp it so tightly that it crushes. If the hose has to cross a floor, choose a route with no sharp bends and keep it out of foot paths.

Signs the drain hose is in the wrong place

Check the setup after the unit has run for a few hours. These signs suggest a routing problem:

  • Water on the floor near the hose end or the unit
  • A sagging section of hose that holds water
  • Dripping or gurgling at the connection
  • The unit stopping, or showing a full-tank warning, even though the hose is connected

If you see any of these, look at the route first. A kink or a low point is a common cause.

Single hose or dual hose

The number of hoses on the unit also matters for the window setup. Single-hose and dual-hose units differ in how they move air, so the window kit may be set up a little differently. For a comparison, see portable air conditioner dual hose vs single. For the full window installation, read the guide on how to install a portable air conditioner in a sliding window.

Drainage and the window seal are separate jobs, so check both. A good drain route will not fix a gap around the panel, and a tight seal will not fix a kinked drain hose.