Short answer
You often cannot tell for certain from the outside. A crack in a furnace or boiler heat exchanger can be hairline and hidden inside the cabinet, and only a technician with the right tools can confirm one. In the meantime, a sounding carbon monoxide alarm, or headaches, dizziness, or nausea in people at home, means you should turn the unit off, get everyone to fresh air, and get help now.
Why a crack is hard to see
The exchanger sits inside the furnace or boiler. One side faces the air or water being heated, and the other side carries combustion gases. The side that matters most is hard to reach without taking the unit apart. A crack can also open and close as the unit heats and cools, so it may not show up on a quick look.
Removing the access panels exposes gas and electrical parts, so leave that work to a technician.
Signs that point toward a crack
- Yellow, flickering, or lifting burner flames, instead of steady blue ones.
- Soot, scorch marks, or rust near the burners, the flue, or the cabinet.
- A burning or unusual smell that continues while the furnace runs.
- Water or staining near the furnace or its vent pipe.
- Repeated shutdowns or short cycling.
- A carbon monoxide alarm, or people at home with symptoms that ease when they go outside.
- For a boiler, water loss or pressure that keeps dropping with no leak you can find.
Quick checks you can do safely
- Look at the flame through the sight window, if your unit has one, from outside the cabinet. Do not open panels or touch the burners.
- Check the carbon monoxide alarm. Make sure it works, has not expired, and is near the sleeping areas.
- Look from the outside for soot, staining, rust, or a flue pipe that looks loose or disconnected.
- Write down what you notice, including when it happens, such as only when the furnace runs for a long time. Note the unit’s age and its service history. A technician will ask.
What a technician can confirm
A licensed technician can check the exchanger in ways you cannot:
- Combustion analysis measures the gases in the flue. It shows how the unit is burning and venting.
- Visual inspection with the burner assembly removed, using a light, a mirror, or a camera.
- Leak test or smoke test to see whether air or combustion gases pass through the exchanger wall.
The full list of signs is in our guide to hvac cracked heat exchanger problems, which covers both furnaces and boilers.
What to do now
If you cannot rule out a crack, do not keep running the unit to see whether it gets better. Turn it off and call a licensed HVAC technician. For a boiler that keeps losing water, stop topping it up, because that can hide the problem.
Do not seal the crack yourself. Tape, silicone, and furnace cement are not a repair for a heat exchanger.