Compressor Problems

House Air Conditioner Compressor Not Turning On

Why an AC compressor won't turn on, safe checks to try first, common causes such as capacitors and safety switches, and when to call a licensed technician.

On this page
  1. What the compressor does
  2. Safe checks to make before calling for service
  3. Common reasons the compressor will not start
  4. Signs that call for a technician sooner
  5. Safety comes first
  6. Repair or replace?
  7. Keeping the compressor from failing

A house air conditioner compressor that won’t turn on is often caused by a power, control, or safety-device problem rather than a dead compressor. Start with simple checks at the thermostat, the breaker, and the outdoor disconnect. If the outdoor unit still will not run, or you notice burning, ice, or repeated breaker trips, call a licensed technician. Work on high-voltage parts is not a do-it-yourself job.

What the compressor does

The compressor is the pump in the outdoor unit of a typical central air conditioner or heat pump. It squeezes refrigerant gas, which raises the gas’s pressure and temperature. At the outdoor coil the refrigerant releases heat to the outside air and cools. It then travels indoors, where it absorbs heat from your home at the indoor coil. The cycle repeats while the thermostat calls for cooling.

When the compressor does not start, the indoor blower may still run. That can make it look as if the system is trying, but no cooling is happening.

Because the compressor draws a lot of electrical current, several controls protect it. Many no-start complaints trace back to power or control problems rather than a dead compressor, so it helps to check the simpler things first.

Safe checks to make before calling for service

Start with checks that do not require opening any panels. For a wider list of checks, see how to troubleshoot home air conditioner problems.

  • Thermostat. Confirm it is set to cool, the set temperature is below the indoor temperature, and the display responds. If the screen is blank, check the batteries first.
  • Air filter. A clogged filter restricts airflow, which can freeze the indoor coil and shut the system down. If the filter is dirty, replace it and see whether the system recovers.
  • Breaker panel. Look for the breaker that serves the air conditioner. If it has tripped, reset it once. If it trips again soon after, stop and call a technician, because a repeat trip means something is drawing too much current or has a fault.
  • Outdoor disconnect. Many outdoor units have a disconnect box mounted on the wall near the unit. Confirm the disconnect is fully in place. Do not open the electrical box.
  • Listen at the outdoor unit. From a safe distance, note whether the outdoor fan runs and whether you hear a hum. A hum with no motion can point to a failed capacitor, or to a compressor that is trying and failing to start. If the outdoor fan is also silent, the problem may overlap with home ac condenser fan not spinning, which covers that symptom in more detail.
  • Give it time. If the system just lost power or was switched off, wait before testing again. Repeated on-and-off cycling can stress the compressor.

After these checks, switch the system off at the thermostat before going any further.

Common reasons the compressor will not start

Thermostat and control problems

The thermostat sends a low-voltage signal to the control board to call for cooling. A failed thermostat, a loose low-voltage wire, or a blown fuse on the control board can stop that signal from reaching the outdoor unit. In that case the indoor fan may run while the outdoor unit stays silent. A technician can test the signal quickly.

A failed contactor

The contactor is a heavy-duty relay that closes to send high-voltage power to the compressor and the outdoor fan. Its contacts can wear or pit over time. A worn contactor may click without closing, or not click at all. The part is often inexpensive, but replacing it involves high voltage, so it belongs with a professional.

A weak or failed capacitor

Capacitors give the compressor and fan motors the extra push they need to start and keep running. A weak or failed capacitor is a frequent cause of a unit that hums, tries to start, and then stops, or that does not start at all. Capacitors can hold a charge after power is removed, so this is not a do-it-yourself job. Capacitors and contactors are among the parts that wear out most often. For context, see what is the most common part to fail on an ac unit.

Tripped safety controls

Air conditioners have built-in protection. A high-pressure switch can shut the compressor down when pressure rises too far, often because of a dirty condenser coil or poor airflow. A low-pressure switch can do the same when refrigerant is low, which usually means a leak. A thermal overload can open when the compressor overheats. These controls are doing their job. They signal that something needs attention, and resetting them over and over without finding the cause can lead to more damage.

Adding refrigerant without repairing the leak is not a lasting fix. Before paying for a recharge, ask the technician to find the leak. Many people also ask how much does it cost to refill refrigerant in an ac unit, but the leak repair is usually the bigger question.

The restart delay

Many systems wait a few minutes before the compressor can start again after it shuts off. The delay protects the compressor from short cycling, which is rapid on-and-off running that can wear it out. If the unit stays quiet right after a shutdown or a power interruption, give it several minutes before concluding there is a fault. For more on this timing, see what is the 3-minute rule for air conditioners.

A failed compressor

When the compressor’s internal motor has failed or the compressor has seized, it may hum without starting, or it may make no sound at all. A failed compressor usually needs replacement, but it should be the last thing a technician confirms. The compressor often gets blamed when a cheaper part, such as a capacitor, a contactor, or a control, is the real problem.

Signs that call for a technician sooner

  • The breaker trips again soon after you reset it.
  • You smell something burning, see scorch marks, or notice discolored wiring at the outdoor unit. Do not touch the unit. Turn the system off at the thermostat and call for service.
  • You see ice on the refrigerant lines or the outdoor coil, or oil stains on the lines.
  • The compressor makes grinding, knocking, or loud buzzing sounds.
  • Cooling has been weak or absent for several days, or the problem returns after a reset.

Safety comes first

Before any hands-on work, switch off power at the thermostat and at the outdoor disconnect. High voltage can remain at the outdoor unit even when the thermostat is off, so the disconnect matters. Capacitors can hold a charge after power is removed. Refrigerant handling in the United States requires EPA Section 608 certification, so it belongs to a trained technician. If you are not sure whether a step is safe, stop and call a licensed technician.

Repair or replace?

A compressor failure can be one of the larger repairs on a home AC system. The right choice depends on the unit’s age, its efficiency, the cost of the repair, and whether the compressor is still under warranty. Costs vary by region and by equipment, so get more than one written estimate and compare each quote with the age of the unit. If the system is near the end of its expected life, you may find more guidance in when to replace heating and air conditioning.

Keeping the compressor from failing

Regular maintenance catches many problems early:

  • Schedule a tune-up once a year, ideally before the cooling season. A technician can check refrigerant charge and pressures, electrical connections, capacitors, and contactors.
  • Keep the outdoor coil clean. Dirt and debris restrict airflow and make the compressor work harder. You can learn how to clean your air conditioner condenser unit safely with the power switched off.
  • Keep the area clear. Trim vegetation and keep leaves and grass away from the outdoor unit, following the clearance the manufacturer specifies.
  • Change the air filter on schedule. A clean filter keeps airflow steady.
  • Avoid repeated on-and-off cycling. Frequent switching can stress the compressor, so let the system run its normal cycle.