The short answer
A COP of 3.5 is generally considered a good figure for a heat pump, but only under the conditions where it was measured. It does not tell you how the heat pump will perform over a whole winter, and it does not guarantee your running costs.
What a COP of 3.5 means
COP, or coefficient of performance, is the ratio of heat delivered to electricity used. A COP of 3.5 means the heat pump delivers about 3.5 units of heat for each unit of electricity, under the test conditions.
One kilowatt-hour of electricity is about 3,412 BTU. A COP of 3.5 therefore corresponds to roughly 12,000 BTU of heat from one kilowatt-hour, which is about 3.5 times what a resistance heater would produce from the same electricity.
Why test conditions matter
A COP always comes with the outdoor and indoor temperatures at which it was measured. Heat pump tests often use an outdoor temperature around 47°F as a common reference point. Heat pumps usually lose efficiency as outdoor air gets colder, because there is less heat to extract and the unit has to work harder.
A COP of 3.5 at 47°F may be noticeably lower at a much colder temperature. Check the manufacturer’s data at several temperatures, not just one.
Converting a seasonal rating to a rough COP
Seasonal ratings give a better picture of annual performance. HSPF is measured in BTU of heat per watt-hour of electricity, and one watt-hour is about 3.412 BTU. Dividing an HSPF value by 3.412 gives an approximate seasonal COP. For example, an HSPF of 10 works out to a seasonal COP of about 2.9.
The newer HSPF2 scale generally gives lower numbers for the same unit, so the conversion is only a rough guide. Use the manufacturer’s data for real comparisons.
What affects heat pump efficiency in practice
- Outdoor temperature. Colder air lowers both output and COP.
- Defrost cycles. In cold, damp weather, the outdoor coil can frost. The unit then defrosts, which temporarily reduces the heat it delivers.
- Backup heat. Electric resistance strips or another heat source may run in very cold weather or while the house recovers from a setback. They are far less efficient than the heat pump itself.
- Ductwork and airflow. Leaks and restrictions reduce how much of the heat reaches the rooms.
- Thermostat settings. Large temperature setbacks can trigger backup heat. Keep changes moderate and follow the manufacturer’s guidance.
Is a COP of 3.5 good enough for your home?
Running cost depends on both the COP and the price of electricity. As a rough guide, the cost of each unit of heat is the electricity price divided by the COP, so a higher COP lowers that cost. Whether heat pumps are more expensive to run than gas furnaces depends mostly on local energy prices, not on COP alone.
A heat pump that struggles to keep the house warm on the coldest days is a separate problem from its COP. If the house still feels cold, check sizing, airflow and thermostat settings first. A heat pump that cannot keep up is the subject of a common question: why is my house so cold with a heat pump?
What to check on a spec sheet
- COP or capacity at several outdoor temperatures
- The seasonal rating (HSPF2)
- Whether the unit is rated for cold climates
- Whether it needs backup heat, and how that heat is controlled
Bottom line
A COP of 3.5 is a strong figure for a heat pump under the conditions where it was measured. Read it together with seasonal ratings, the temperatures where you live, and your local electricity prices to judge the real running cost.