A heat pump system has two main sections, an outdoor unit and an indoor unit, joined by refrigerant lines and controlled by a thermostat. Inside those units are a compressor, coils, a fan or blower, a reversing valve and a few supporting parts. Each one has a job in moving heat into or out of the house.
The outdoor unit
The compressor is the pump at the center of the system. It squeezes refrigerant gas, which raises the refrigerant’s pressure and temperature so it can carry heat from one coil to the other. A compressor failure is one of the more expensive repairs on any heat pump, so it is worth checking that the unit has been serviced regularly.
The outdoor coil is a finned coil that exchanges heat with the outside air. In heating mode it absorbs heat from the air. In cooling mode it releases heat to the air.
The outdoor fan moves air across the outdoor coil so the heat exchange can happen. A fan that is not spinning can keep the system from working properly.
The reversing valve is what lets one system both heat and cool. It changes the direction of refrigerant flow, so the indoor coil releases heat in heating mode and absorbs heat in cooling mode.
The metering device, often an expansion valve, controls how much refrigerant reaches a coil and lowers its pressure before it enters that coil. Depending on the design, it sits near the indoor coil or the outdoor coil.
The defrost control handles frost. When the outdoor coil gets cold enough to frost during heating, the system can briefly reverse to send warm refrigerant to the outdoor coil and melt the frost.
The indoor unit
In a ducted system, the indoor unit is an air handler that holds the indoor coil, the blower and the air filter. In a ductless mini split, the indoor head is a wall, ceiling or floor unit that contains the coil, the fan and the filter in one housing.
The indoor coil is the other half of the heat exchange. In heating mode it releases heat into the air passing over it. In cooling mode it absorbs heat from the indoor air, and water condenses on it, which is why it needs a drain.
The blower moves air through the ducts or, in a mini split, across the indoor coil and back into the room.
The air filter traps dust and debris before the air reaches the coil. A dirty filter cuts airflow, and in some cases that can lead to a frozen coil.
Some ducted systems also have electric backup heat, often called strip heat, in the air handler. It runs when extra heat is needed on very cold days.
Connecting parts
Refrigerant lines are the copper pipes that carry refrigerant between the outdoor and indoor units. They are usually insulated. In ductless systems, the refrigerant lines are often bundled with the power and control wiring.
The condensate drain carries away the water that forms on the indoor coil during cooling. A blocked drain can cause water to leak into the home.
Low-voltage control wiring links the thermostat with the equipment. It carries the signals that start and stop the compressor, the fans and any backup heat.
The thermostat sets the target temperature and tells the system when to run. In a mini split, the controls may be a handheld remote or built into the indoor unit.
Parts owners can check
Most owners can check the air filter, keep the outdoor coil clear of leaves and debris, and make sure the condensate drain is not blocked. Work on the compressor, reversing valve or refrigerant circuit, and any work on live electrical parts, should be left to a licensed technician.
The exact parts depend on the type of system. A packaged unit keeps the same parts in one outdoor cabinet, and a mini split has no ducts but still has an outdoor coil, a compressor and an indoor coil.